Enter what’s on your vial and syringe below and it does the arithmetic. Nothing you type is stored or sent anywhere.
Educational tool, not medical advice. This calculator converts between vial content, added liquid, and draw amount. It does not tell you what amount is appropriate, safe, or effective for any purpose, and inclusion of a compound type here is not an endorsement or recommendation. Consult a qualified, licensed healthcare professional about anything concerning your own health.
What this peptide reconstitution calculator does
This peptide reconstitution calculator turns three numbers from your vial and syringe into the others. Enter the amount in the vial, the liquid added and the amount you want to measure, and it shows where the liquid sits on a U-100 insulin syringe. Or work backward to find how much liquid to add. It shows concentration and amount per syringe unit, runs in your browser, and does arithmetic only.
It has two tabs. Each one runs the same math in a different direction.
| Tab | You enter | You get back |
|---|---|---|
| Draw volume | Amount in the vial, liquid added in mL, the amount to measure, and the syringe size | The syringe mark in units, the same volume in mL, the concentration, the amount per syringe unit, the number of full amounts in the vial, and the total in the vial |
| How much water | Amount in the vial, the amount to measure, and the syringe mark you want that amount to land on | The liquid to add in mL, plus the same readouts |
Choose Peptide, HCG or HGH first. That choice sets which units are available. Then match the syringe size (0.3 mL, 0.5 mL or 1 mL) to the syringe in your hand. A drawing of the syringe fills to the answer, so you can check the result by eye.
How to read the result
“Draw volume” starts from the amount already in the vial, how much liquid was added, and the single dose you want, and returns where to draw to on the syringe barrel. “How much water” runs the same math in reverse: pick a round number on the syringe you’d like each dose to land on, and it returns how much liquid to add to the vial.
IU (international units) measures potency, not mass, and the conversion between the two is different for every compound. This tool does not include a general-purpose IU-to-mg converter for that reason. The one fixed exception is HGH (somatropin), where 1 mg is a standard 3 IU; every other unit shown is a direct read of what was entered.
The math behind the calculator
Everything the calculator shows comes from four short formulas. You can check any result by hand.
- Concentration = amount in the vial ÷ liquid added. A vial holding 5 mg with 2 mL added makes a liquid with 2.5 mg in every mL.
- Volume to measure = amount wanted ÷ concentration.
- Syringe units = volume in mL × 100, because a U-100 syringe has 100 units in every mL.
- Liquid to add (the How much water tab) = amount in the vial × syringe units wanted ÷ (100 × amount wanted).
Here is a made-up example that only shows the arithmetic. It is not an amount for any compound. A vial holds 5 mg, which is 5,000 mcg. Adding 2 mL gives 2,500 mcg in every mL. One syringe unit is 0.01 mL, so each unit holds 25 mcg (2,500 ÷ 100). Ten units, which is 0.1 mL, hold 250 mcg.
A shortcut for peptides in mg: mcg per syringe unit = mg in the vial × 10 ÷ mL of liquid added. For the same example, 5 × 10 ÷ 2 = 25.
Peptide per syringe unit, by vial size and liquid added
This table is arithmetic only. It uses round example numbers. It is not a dose, and it does not suggest a vial size or an amount of liquid. Every value is mcg in one syringe unit (0.01 mL), rounded to one decimal. Multiply a value by the number of units to get the amount in that volume.
| Vial contents | 1 mL added | 2 mL added | 3 mL added | 5 mL added |
|---|---|---|---|---|
| 5 mg | 50 | 25 | 16.7 | 10 |
| 10 mg | 100 | 50 | 33.3 | 20 |
| 15 mg | 150 | 75 | 50 | 30 |
| 20 mg | 200 | 100 | 66.7 | 40 |
| 30 mg | 300 | 150 | 100 | 60 |
Read across a row and the same vial gets more dilute as more liquid is added. Read down a column and a larger vial has more peptide in each unit at the same volume. The vial itself never changes. Only the concentration does. The full explanation is in how much water to add to a peptide vial.
Unit conversions the calculator uses
| Conversion | Value | Applies to |
|---|---|---|
| 1 mg | 1,000 mcg | Any weight |
| 1 mL | 100 units | U-100 insulin syringes only |
| 1 syringe unit | 0.01 mL | U-100 insulin syringes only |
| 0.3 mL, 0.5 mL and 1 mL barrels | 30, 50 and 100 units | U-100 insulin syringes |
| 1 mg of somatropin (HGH) | 3 IU | Somatropin only |
| HCG | Labelled in IU, no mass conversion | Chorionic gonadotropin |
A syringe unit measures liquid. An IU measures biological activity. They share a word but are different things. The units guide explains the difference.
What the Peptide, HCG and HGH settings change
| Setting | Vial amount entered in | Amount to measure entered in | Conversion used |
|---|---|---|---|
| Peptide | mg | mcg or mg | 1 mg = 1,000 mcg |
| HCG | IU | IU | None. Vials are labelled in IU or USP units |
| HGH | IU or mg | IU or mg | 1 mg of somatropin = 3 IU |
The 3 IU per mg factor comes from product labelling for somatropin (see Sources). It applies to somatropin only, not to HCG and not to any peptide. The calculator has no general IU to mg converter on purpose, because that factor is different for every substance.
Warnings the calculator shows
The calculator checks your numbers and shows a message when a result looks wrong. These are the cases it flags.
- The draw is larger than the syringe barrel, so it will not fit the size you picked.
- The result is under 3 units. A very small mark is hard to read accurately.
- The amount to measure is larger than the whole vial.
- On the How much water tab: the syringe mark you asked for is larger than the barrel, or the liquid to add is more than 5 mL and may not fit in the vial.
Mistakes a calculator cannot catch
- The wrong unit. mg and mcg differ by a factor of 1,000. ISMP warns that the micrograms symbol can be mistaken for mg and recommends writing “mcg”.
- Units read as milliliters. ISMP names this as a recognized source of insulin errors.
- Syringe markings that differ. Scales vary by size and maker. Count the lines on your own syringe (see how to read an insulin syringe).
- Changing the liquid after the math. If the volume added differs from the one you entered, every number that follows is wrong.
- What is in the vial. The calculator only knows what you type. It cannot tell you how much is really in the vial. See how to read a peptide test report.
Common questions
How do I use a peptide reconstitution calculator?
Choose Peptide, HCG or HGH. Use the Draw volume tab if the liquid is already in the vial, or the How much water tab to work out how much liquid to add. Enter the amount printed on the vial, the liquid added or the syringe mark you want, and the amount you are measuring, then pick your syringe size. The result shows the syringe mark, the volume in mL, the concentration and the amount per syringe unit. Check it against the formulas on this page.
How many units is 0.1 mL on a U-100 insulin syringe?
10 units. One unit on a U-100 syringe is 0.01 mL, and 100 units is 1 mL.
How many mcg are in a mg?
1,000. Multiply mg by 1,000 to get mcg, and divide mcg by 1,000 to get mg.
How many mcg are in one syringe unit?
It depends on the vial and the liquid added. For a peptide, mcg per unit equals the mg in the vial multiplied by 10, then divided by the mL of liquid added. A 5 mg vial with 2 mL added works out to 25 mcg per unit. The reference table above shows more combinations. These are arithmetic examples, not amounts for any compound.
Does adding more water change how much peptide is in the vial?
No. The vial holds the same amount either way. More liquid makes the solution more dilute, so each syringe unit holds less.
Is a syringe unit the same as an IU?
No. A unit on a U-100 insulin syringe is 0.01 mL of liquid. An International Unit measures biological activity, and it converts to weight only with a factor specific to one substance.
Does the calculator convert IU to mg?
Only for HGH, using 1 mg of somatropin as 3 IU. HCG vials are labelled in IU, so no mass conversion is used. It has no IU to mg converter for other substances because the factor differs for every substance.
Does this calculator say how much to use?
No. It only converts between the numbers you enter. It does not suggest an amount, and a number in an example is not a recommendation. Reported amounts for individual compounds, with sources and evidence grades, are on each compound page in the A-Z index. They document what is reported, not what anyone should do. See how we grade evidence. Talk with a licensed healthcare professional about anything concerning your own health.
Is anything I type saved or sent?
No. The calculation runs in your browser, and the page does not store or send what you enter.
What happens if the answer is bigger than the syringe?
The calculator shows a warning that the draw does not fit the syringe size you selected. Check the numbers you entered first.
Keep reading
- mg, mcg, IU and syringe units explained: why a syringe unit is not an IU, and how to avoid 1,000-fold mistakes
- How to read an insulin syringe: 0.3, 0.5 and 1 mL syringes, and why scales differ
- How much water to add to a peptide vial: the math behind concentration, with a worked table
- How to reconstitute a peptide, step by step: the sterile-technique steps, and what nobody has established
- Bacteriostatic water vs sterile water: what is in each bottle and what the labels say
- How to store peptides: storage guidance and its limits
- What lyophilized means, and what looks wrong: how to read the look of a freeze-dried vial
- How to read a peptide test report (COA): purity vs content, and what a report cannot prove
- Subcutaneous injection basics: sites, rotation, the one-time-use rule and sharps disposal
- Peptide A-Z index: every compound entry, with sources and evidence tiers
- How we grade evidence: what the tiers mean
Sources
- ISMP List of Error-Prone Abbreviations, Symbols, and Dose Designations (2024), ISMP/ECRI
- CORRECTION: ISMP warns about insulin administration errors (Aug 16, 2011), Drug Topics, reporting ISMP
- Insulin Basics: The Types of Insulin, ADCES
- Providing International biological reference standards, WHO
- Norditropin NordiFlex Summary of Product Characteristics and package leaflet (states 1 mg of somatropin corresponds to 3 IU), Novo Nordisk
- Novarel (chorionic gonadotropin) professional information, Drugs.com